1998 Vol. 16, No. 4
Display Method:
1998, (4): 193-195.
Abstract:
The pharmacokineties of vitamine E microcapsules were studied. Concentration of plasma was determined by UV after ig 100mg/kg Vitamin E of vitamin E microcapsules being given rabbits.The pharmacokineties of vitamin E fitted to a two-compartment medal...
The pharmacokineties of vitamine E microcapsules were studied. Concentration of plasma was determined by UV after ig 100mg/kg Vitamin E of vitamin E microcapsules being given rabbits.The pharmacokineties of vitamin E fitted to a two-compartment medal...
1998, (4): 218-220.
Abstract:
We studied the method of preparation and qulality control of compound ofloxacin ear drop.The determination of ofloxacin was established by ultroaviolet spectrophotometry at the wavelength 293nm. The stability of compound ofloxacin ear drops were test...
We studied the method of preparation and qulality control of compound ofloxacin ear drop.The determination of ofloxacin was established by ultroaviolet spectrophotometry at the wavelength 293nm. The stability of compound ofloxacin ear drops were test...
1998, (4): 222-224.
Abstract:
The stability of aminophylline in four transfusion solutions were studied. The result showed that aminophylline was stable when combined with 0.9% sodium chloride injection under 25℃ and 37℃, their appearances, pH, ultraviolet spectrum and content ha...
The stability of aminophylline in four transfusion solutions were studied. The result showed that aminophylline was stable when combined with 0.9% sodium chloride injection under 25℃ and 37℃, their appearances, pH, ultraviolet spectrum and content ha...
1998, (4): 230-232.
Abstract:
A method of determination by UV spectrophotometry and identification by thin-layer chromatography of tetracaine hydrochloride eye drop was established. The maximum absorbance wavel ength at 310±1nm was selected for determination wavelength, ethyl hyd...
A method of determination by UV spectrophotometry and identification by thin-layer chromatography of tetracaine hydrochloride eye drop was established. The maximum absorbance wavel ength at 310±1nm was selected for determination wavelength, ethyl hyd...
1998, (4): 232-233.
Abstract:
The contente of sodium chloride injection was determinated by conductance. The recovery is 99.97%, RSD=0.32%. This method is simple, rapid and accurate.
The contente of sodium chloride injection was determinated by conductance. The recovery is 99.97%, RSD=0.32%. This method is simple, rapid and accurate.