Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

YUE Chang-lin, GUO Zhong. Quantitative determination of content in Busulfan's tablets by HPLC-ELSD[J]. Journal of Pharmaceutical Practice and Service, 2006, (1): 25-27.
Citation: YUE Chang-lin, GUO Zhong. Quantitative determination of content in Busulfan's tablets by HPLC-ELSD[J]. Journal of Pharmaceutical Practice and Service, 2006, (1): 25-27.

Quantitative determination of content in Busulfan's tablets by HPLC-ELSD

  • Received Date: 2005-07-08
  • Objective :To establish a HPLC-ELSD method for determining the content of busulfan in busulfan tablets. Methods : The chromatographic conditions were as follows:SHIMADZU C8 column(250mm×4.6mm,5μm),the mobile phase:water-acetonitrile (75-25),the flow rate:1.0mL/min,and the detector:ELSD,the carrier gas:nitrogen,the flow rate:2.0 bar. Results :The standard curve of busulfan was linear over the rage of 0. 25-0.75mg/mL(r=0.9999).The average recovery was 99.7%. Conclusion :This method is accurate and specificity,and it can be used on the quality control of busulfan tablets.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2025) PDF downloads(187) Cited by()

Related
Proportional views

Quantitative determination of content in Busulfan's tablets by HPLC-ELSD

Abstract: Objective :To establish a HPLC-ELSD method for determining the content of busulfan in busulfan tablets. Methods : The chromatographic conditions were as follows:SHIMADZU C8 column(250mm×4.6mm,5μm),the mobile phase:water-acetonitrile (75-25),the flow rate:1.0mL/min,and the detector:ELSD,the carrier gas:nitrogen,the flow rate:2.0 bar. Results :The standard curve of busulfan was linear over the rage of 0. 25-0.75mg/mL(r=0.9999).The average recovery was 99.7%. Conclusion :This method is accurate and specificity,and it can be used on the quality control of busulfan tablets.

YUE Chang-lin, GUO Zhong. Quantitative determination of content in Busulfan's tablets by HPLC-ELSD[J]. Journal of Pharmaceutical Practice and Service, 2006, (1): 25-27.
Citation: YUE Chang-lin, GUO Zhong. Quantitative determination of content in Busulfan's tablets by HPLC-ELSD[J]. Journal of Pharmaceutical Practice and Service, 2006, (1): 25-27.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return