Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

Wang Xiao-bo, Wang Jing-guo, Xi Rong-gang. Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin[J]. Journal of Pharmaceutical Practice and Service, 2002, (5): 293-295.
Citation: Wang Xiao-bo, Wang Jing-guo, Xi Rong-gang. Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin[J]. Journal of Pharmaceutical Practice and Service, 2002, (5): 293-295.

Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin

  • Received Date: 2002-04-22
  • OBJECTIVE To develop a method for assay of roxithromycin in electron medicinal membrane of roxithromycin. METHODS To use a HPLC method by YWG C18 column. The mobile phase was a mixture of acetonitrile-methano-l0.5% ammonium acetate(100:80:60),with the detection wavelength at 235 nm.RESULTS Precision and stability were fine. The linear correlation was observed from the concentrations of 0.3 to 1.7mg·ml-1(r=0.9998).The average recovery was 99.23%.Resolution bettween roxithromycin and other peaks met the requirements.CONCLUSION The method is convenient, selective and reproducible.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2664) PDF downloads(559) Cited by()

Related
Proportional views

Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin

Abstract: OBJECTIVE To develop a method for assay of roxithromycin in electron medicinal membrane of roxithromycin. METHODS To use a HPLC method by YWG C18 column. The mobile phase was a mixture of acetonitrile-methano-l0.5% ammonium acetate(100:80:60),with the detection wavelength at 235 nm.RESULTS Precision and stability were fine. The linear correlation was observed from the concentrations of 0.3 to 1.7mg·ml-1(r=0.9998).The average recovery was 99.23%.Resolution bettween roxithromycin and other peaks met the requirements.CONCLUSION The method is convenient, selective and reproducible.

Wang Xiao-bo, Wang Jing-guo, Xi Rong-gang. Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin[J]. Journal of Pharmaceutical Practice and Service, 2002, (5): 293-295.
Citation: Wang Xiao-bo, Wang Jing-guo, Xi Rong-gang. Studies on assay of roxithromycin in electron medicinal membrane of roxithromycin[J]. Journal of Pharmaceutical Practice and Service, 2002, (5): 293-295.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return