Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

YANG Fanping, LI Guowen, XI Yan. Study on improvement of quality standard for Kechuan Liuwei oral liquid[J]. Journal of Pharmaceutical Practice and Service, 2019, 37(1): 55-58,85. doi: 10.3969/j.issn.1006-0111.2019.01.013
Citation: YANG Fanping, LI Guowen, XI Yan. Study on improvement of quality standard for Kechuan Liuwei oral liquid[J]. Journal of Pharmaceutical Practice and Service, 2019, 37(1): 55-58,85. doi: 10.3969/j.issn.1006-0111.2019.01.013

Study on improvement of quality standard for Kechuan Liuwei oral liquid

doi: 10.3969/j.issn.1006-0111.2019.01.013
  • Received Date: 2018-07-02
  • Rev Recd Date: 2018-09-10
  • Objective To improve the quality control standard of the hospital preparation Kechuan Liuwei oral liquid in Longhua Hospital. Methods TLC was used for qualitative identification of Scutellaria baicalensis Georgi and Asarum sieboldi Mig in the Kechuan Liuwei oral liquid. Ephedrine and Baicalin content in ephedra and Scutellaria were determined by HPLC with Welch-C18 column (4.6mm×250mm, 5 μm). Acetonitrile-0.1% phosphoric acid solution (4:96) and methanol-0.1% phosphoric acid solution (47:53) were used as mobile phase. The detection wavelengths were 206 nm and 278 nm respectively. The flow rate was 1.0 ml/min. Results The TLC spots of Scutellaria baicalensis Georgi and asarum were clear without interference of the negative control. The linear range of Ephedrine hydrochloride was within 12.04-301.00 μg/ml (r=0.999 9). The average recovery was 101.7% (RSD=1.5%). The linear range of Pseudoephedrine hydrochloride was within 7.98-199.40 μg/ml (r=0.999 9). The average recovery was 101.6% (RSD=2.4%). The linear range of Baicalin was within 5.18-129.50 μg/ml (r=0.999 9). The average recovery was 101.0% (RSD=0.3%). Conclusion The qualitative identification and the active ingredient assay method established in this experiment were simple and feasible. Those methods can be used as the quality control standard for Kechuan Liuwei oral liquid.
  • [1] 尹良胜.吴银根教授中医药治疗哮喘经验[J].上海中医药杂志,2006,20(4):62-63.
    [2] 倪伟,吴银根,张惠勇,等.咳喘落治疗支气管哮喘寒哮证多中心临床研究[J].上海中医药大学学报,2007,21(3):43-45.
    [3] 国家药典委员会.中华人民共和国药典(四部):2015年版[S].北京:中国医药科技出版社,2015:57.
    [4] 顾俊.川芎茶调散的质量标准研究[J].中国冶金工业医学杂志,2014,31(4):474-475.
    [5] 周斌,刘可越,刘海军,等.RP-HPLC法测定麻黄配方颗粒中麻黄碱和伪麻黄碱的含量[J].天津药学,2009,21(4):9-11.
    [6] 先春,龚小见,赵超,等.虎耳草的化学成分研究[J].中国实验方剂学杂志,2012,18(10):124-126.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3312) PDF downloads(437) Cited by()

Related
Proportional views

Study on improvement of quality standard for Kechuan Liuwei oral liquid

doi: 10.3969/j.issn.1006-0111.2019.01.013

Abstract: Objective To improve the quality control standard of the hospital preparation Kechuan Liuwei oral liquid in Longhua Hospital. Methods TLC was used for qualitative identification of Scutellaria baicalensis Georgi and Asarum sieboldi Mig in the Kechuan Liuwei oral liquid. Ephedrine and Baicalin content in ephedra and Scutellaria were determined by HPLC with Welch-C18 column (4.6mm×250mm, 5 μm). Acetonitrile-0.1% phosphoric acid solution (4:96) and methanol-0.1% phosphoric acid solution (47:53) were used as mobile phase. The detection wavelengths were 206 nm and 278 nm respectively. The flow rate was 1.0 ml/min. Results The TLC spots of Scutellaria baicalensis Georgi and asarum were clear without interference of the negative control. The linear range of Ephedrine hydrochloride was within 12.04-301.00 μg/ml (r=0.999 9). The average recovery was 101.7% (RSD=1.5%). The linear range of Pseudoephedrine hydrochloride was within 7.98-199.40 μg/ml (r=0.999 9). The average recovery was 101.6% (RSD=2.4%). The linear range of Baicalin was within 5.18-129.50 μg/ml (r=0.999 9). The average recovery was 101.0% (RSD=0.3%). Conclusion The qualitative identification and the active ingredient assay method established in this experiment were simple and feasible. Those methods can be used as the quality control standard for Kechuan Liuwei oral liquid.

YANG Fanping, LI Guowen, XI Yan. Study on improvement of quality standard for Kechuan Liuwei oral liquid[J]. Journal of Pharmaceutical Practice and Service, 2019, 37(1): 55-58,85. doi: 10.3969/j.issn.1006-0111.2019.01.013
Citation: YANG Fanping, LI Guowen, XI Yan. Study on improvement of quality standard for Kechuan Liuwei oral liquid[J]. Journal of Pharmaceutical Practice and Service, 2019, 37(1): 55-58,85. doi: 10.3969/j.issn.1006-0111.2019.01.013
Reference (6)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return