Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

Wang Yanping, Liu Fuqiang, Wang Weidong, Liu Ge. Study on the method of dissolution test of norfloxacin Capsule[J]. Journal of Pharmaceutical Practice and Service, 1999, (4): 230-232.
Citation: Wang Yanping, Liu Fuqiang, Wang Weidong, Liu Ge. Study on the method of dissolution test of norfloxacin Capsule[J]. Journal of Pharmaceutical Practice and Service, 1999, (4): 230-232.

Study on the method of dissolution test of norfloxacin Capsule

  • Received Date: 1999-03-10
  • OBJECTIVE To study the condition and method using UV-spectrophotomery for determining the concentration and dissolution of Norfloxacin capsule.METHODS The concentration of Norfloxacin capsule was detected by UV-spectrophotometry and the dissolution was detected by rotation basket method.RESULTS The iggest absorbtion was at 273nm wavelength(5μg/ml,0.4% NaOH solution).The average absorption coefficient(E1cm1%)is 1095,And the linear relationship was good(r=0 9998)In 20minutes,the dissolution rates were 80%.CONCLUSION The concentration of Norfloxacin can be detected by UV-spectrophotometry,it′s convient and rapid.It can also be wsed to detect the dvssolution of Norfloxacin capsule.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2592) PDF downloads(1008) Cited by()

Related
Proportional views

Study on the method of dissolution test of norfloxacin Capsule

Abstract: OBJECTIVE To study the condition and method using UV-spectrophotomery for determining the concentration and dissolution of Norfloxacin capsule.METHODS The concentration of Norfloxacin capsule was detected by UV-spectrophotometry and the dissolution was detected by rotation basket method.RESULTS The iggest absorbtion was at 273nm wavelength(5μg/ml,0.4% NaOH solution).The average absorption coefficient(E1cm1%)is 1095,And the linear relationship was good(r=0 9998)In 20minutes,the dissolution rates were 80%.CONCLUSION The concentration of Norfloxacin can be detected by UV-spectrophotometry,it′s convient and rapid.It can also be wsed to detect the dvssolution of Norfloxacin capsule.

Wang Yanping, Liu Fuqiang, Wang Weidong, Liu Ge. Study on the method of dissolution test of norfloxacin Capsule[J]. Journal of Pharmaceutical Practice and Service, 1999, (4): 230-232.
Citation: Wang Yanping, Liu Fuqiang, Wang Weidong, Liu Ge. Study on the method of dissolution test of norfloxacin Capsule[J]. Journal of Pharmaceutical Practice and Service, 1999, (4): 230-232.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return