Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

XUE Zhi-hong, WANG Sheng-hao, PAN Shi-ru. Determination of doxapram hydrochloride glucose injection by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(1): 64-66. doi: 10.3969/j.issn.1006-0111.2013.01.019
Citation: XUE Zhi-hong, WANG Sheng-hao, PAN Shi-ru. Determination of doxapram hydrochloride glucose injection by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(1): 64-66. doi: 10.3969/j.issn.1006-0111.2013.01.019

Determination of doxapram hydrochloride glucose injection by HPLC

doi: 10.3969/j.issn.1006-0111.2013.01.019
  • Received Date: 2012-04-06
  • Rev Recd Date: 2012-05-17
  • Objective To establish an HPLC method for determination of doxapram hydrochloride glucose injection. Methods COSMOSIL C18 (150 mm×4.6 mm,5 μm) column was adopted. The mobile phase consisted of 0.82 μg/L CH3COONa (using Glacial acetic acid adjust to pH 4.5)-acetonitrile (70:30). The detection wavelength was 214 nm. Results The linearity of doxapram hydrochloride concentration was in the range of 13~91 μg/ml (r=0.999 8). The average recovery was 99.3%,RSD=0.81% (n=9). Conclusion The method was simpleaccurate and sensitive with high specificity.
  • [1] 王 乐.应用拮抗药多沙普仑临床观察[J].中国医师杂志,2004,10(增刊):257.
    [2] 中国药典2010版.二部[S].2010:629.
    [3] 欧洲药典[S].第7版.1893.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3047) PDF downloads(386) Cited by()

Related
Proportional views

Determination of doxapram hydrochloride glucose injection by HPLC

doi: 10.3969/j.issn.1006-0111.2013.01.019

Abstract: Objective To establish an HPLC method for determination of doxapram hydrochloride glucose injection. Methods COSMOSIL C18 (150 mm×4.6 mm,5 μm) column was adopted. The mobile phase consisted of 0.82 μg/L CH3COONa (using Glacial acetic acid adjust to pH 4.5)-acetonitrile (70:30). The detection wavelength was 214 nm. Results The linearity of doxapram hydrochloride concentration was in the range of 13~91 μg/ml (r=0.999 8). The average recovery was 99.3%,RSD=0.81% (n=9). Conclusion The method was simpleaccurate and sensitive with high specificity.

XUE Zhi-hong, WANG Sheng-hao, PAN Shi-ru. Determination of doxapram hydrochloride glucose injection by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(1): 64-66. doi: 10.3969/j.issn.1006-0111.2013.01.019
Citation: XUE Zhi-hong, WANG Sheng-hao, PAN Shi-ru. Determination of doxapram hydrochloride glucose injection by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(1): 64-66. doi: 10.3969/j.issn.1006-0111.2013.01.019
Reference (3)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return