Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.
Citation: LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.

Determination of atropine sulfate eye drops by ion-pair HPLC

  • Received Date: 2004-03-04
  • Objective An ion-pair HPLC method was developed for determination of atropine sulfate in atropine sulfate eye drops. Methods Alltech-C18 (4.6×250mm, 5μm)column was used and the mobile phase was acetonitrile -0.05mol/L sodium hep-tanesul fonate (35:65). It was detected at 210nm. ResultsLinearity was obtained in the concentration rage of 8-120μg/mL, A=-72915.4073 + 15308.1639C,r=0.999. The average recoveries was 100.2%, RSD = 0.65%. Conclusion The method provide a accurate and sensitive way for the determination of atropine sulfate in atropine sulfate eye drops by ion-pair HPLC.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2614) PDF downloads(466) Cited by()

Related
Proportional views

Determination of atropine sulfate eye drops by ion-pair HPLC

Abstract: Objective An ion-pair HPLC method was developed for determination of atropine sulfate in atropine sulfate eye drops. Methods Alltech-C18 (4.6×250mm, 5μm)column was used and the mobile phase was acetonitrile -0.05mol/L sodium hep-tanesul fonate (35:65). It was detected at 210nm. ResultsLinearity was obtained in the concentration rage of 8-120μg/mL, A=-72915.4073 + 15308.1639C,r=0.999. The average recoveries was 100.2%, RSD = 0.65%. Conclusion The method provide a accurate and sensitive way for the determination of atropine sulfate in atropine sulfate eye drops by ion-pair HPLC.

LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.
Citation: LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return