Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

PAN Min-xiang, LIU Chang-ye, CHANG Hua, ZHAO Miao, . Detemination of rutaecarpine In Zuojin Wan by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2002, (4): 236-237.
Citation: PAN Min-xiang, LIU Chang-ye, CHANG Hua, ZHAO Miao, . Detemination of rutaecarpine In Zuojin Wan by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2002, (4): 236-237.

Detemination of rutaecarpine In Zuojin Wan by HPLC

  • Received Date: 2002-03-04
  • OBJECTIVE A quantitative method was developed for the determination of rutaecarpine in Zuojin Wan by HPLC. METHOD The chromatographic conditions include column Intersil C18, mobile phase:acetonitrile-10% acetonitrile (50:50), flow rate 1 ml·min-1, wavelength 345nm. RESULTS The number of theoretical plates caculated by rutaecarpine peak was 2100, The regression equation of rutaecarpine was Y=-0.2197+0.000000349X(r=0.9999) and the liner range was 12-60μg·ml-1. The average recovery of rutaecarpine was 96.9% (n=5),RSD 3.7%. The measurable lowest limit of rutaecarpine was 0.1μg·ml-. CONCLUSION The method is sensitive, rapid and accurate.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1903) PDF downloads(417) Cited by()

Related
Proportional views

Detemination of rutaecarpine In Zuojin Wan by HPLC

Abstract: OBJECTIVE A quantitative method was developed for the determination of rutaecarpine in Zuojin Wan by HPLC. METHOD The chromatographic conditions include column Intersil C18, mobile phase:acetonitrile-10% acetonitrile (50:50), flow rate 1 ml·min-1, wavelength 345nm. RESULTS The number of theoretical plates caculated by rutaecarpine peak was 2100, The regression equation of rutaecarpine was Y=-0.2197+0.000000349X(r=0.9999) and the liner range was 12-60μg·ml-1. The average recovery of rutaecarpine was 96.9% (n=5),RSD 3.7%. The measurable lowest limit of rutaecarpine was 0.1μg·ml-. CONCLUSION The method is sensitive, rapid and accurate.

PAN Min-xiang, LIU Chang-ye, CHANG Hua, ZHAO Miao, . Detemination of rutaecarpine In Zuojin Wan by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2002, (4): 236-237.
Citation: PAN Min-xiang, LIU Chang-ye, CHANG Hua, ZHAO Miao, . Detemination of rutaecarpine In Zuojin Wan by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2002, (4): 236-237.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return