Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

SHENG Feng-xian, XIONG Ke-qiang, WANG Hui-zhi, ZHANG You-jie, GAO Li-ping. Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(2): 107-108,114. doi: 10.3969/j.issn.1006-0111.2012.02.008
Citation: SHENG Feng-xian, XIONG Ke-qiang, WANG Hui-zhi, ZHANG You-jie, GAO Li-ping. Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(2): 107-108,114. doi: 10.3969/j.issn.1006-0111.2012.02.008

Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test

doi: 10.3969/j.issn.1006-0111.2012.02.008
  • Received Date: 2011-12-22
  • Rev Recd Date: 2012-03-06
  • Objective To establish a method for determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test. Methods Based on interference experiment, the endotoxin was added in the samples, whose recovery should be within the range 50%~200%. Results The interference from limulus test was eliminated by diluting the Human coagulation factor Ⅷ (1→100 solution). Conclusions Turbidimetric-kinetic method was feasible, and had the same result with the rabbit-pyretogen test.
  • [1] Van DK, Van Der Bom JG, Lenting PJ, et al. Facter Ⅷ half-life and clinical phenotype of severe hemophilia A [J]. Haematologica, 2005,90(4):494.
    [2] 赵艳华, 马 平, 卜凤荣. 凝血因子分子生物学研究进展[J]. 生物技术通讯,1999,10(2):158.
    [3] 国家药典2010版.三部[S]. 2010:95.
    [4] 劳海燕,罗宇芬,林秋晓.动态比浊法用于检测生脉注射液中细菌内毒素的研究[J].广东药学学报,2002,18(1):21.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3995) PDF downloads(444) Cited by()

Related
Proportional views

Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test

doi: 10.3969/j.issn.1006-0111.2012.02.008

Abstract: Objective To establish a method for determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test. Methods Based on interference experiment, the endotoxin was added in the samples, whose recovery should be within the range 50%~200%. Results The interference from limulus test was eliminated by diluting the Human coagulation factor Ⅷ (1→100 solution). Conclusions Turbidimetric-kinetic method was feasible, and had the same result with the rabbit-pyretogen test.

SHENG Feng-xian, XIONG Ke-qiang, WANG Hui-zhi, ZHANG You-jie, GAO Li-ping. Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(2): 107-108,114. doi: 10.3969/j.issn.1006-0111.2012.02.008
Citation: SHENG Feng-xian, XIONG Ke-qiang, WANG Hui-zhi, ZHANG You-jie, GAO Li-ping. Determination of bacterial endotoxin in human coagulation factor Ⅷ by kinetic turbidimetric limulus test[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(2): 107-108,114. doi: 10.3969/j.issn.1006-0111.2012.02.008
Reference (4)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return